Range of Servo Stabilizer Control Cards
We at Piyush Electronics & Electricals (P) Ltd, manufactures different types of PCB control circuits for Servo Voltage Stabilizer under the brand name PEQVI®.
The firmware is embedded with innovative software algorithms residing on latest technology microcontroller chips. The designs are conceived so as to reduce production overheads like wiring and testing. Our controller modules are entirely designed, developed and manufactured in INDIA in our own factory. We offer an incomparable level of service with one thing in mind - your complete contentment.
Below is the comparision chart of all the existing models of servo control cards.
microServo | intelliServo | Basic Servo Card | ||||
---|---|---|---|---|---|---|
Advanced PIC Microcontroller based, indigenous design | ||||||
Advanced PIC Microcontroller based, indigenous design | ✔ | ✔ | ✔ | |||
Panel mounted ergonomic design with easy to operate keys | ||||||
Panel mounted ergonomic design with easy to operate keys | ✔ | ✔ | ||||
Full integrated drive for AC Synchronous Servo Motor | ||||||
Full integrated drive for AC Synchronous Servo Motor | ✔ | ✔ | ✔ | |||
Bright 3 digit, 7 Segment LED Display | ||||||
Bright 3 digit, 7 Segment LED Display | ✔ | ✔ | ||||
Display Parameters: Input Voltage, Output Voltage | ||||||
Display Parameters: Input Voltage, Output Voltage | ✔ | ✔ | None | |||
Display Parameters Frequency, Load Current | ||||||
Display Parameters Frequency, Load Current | ✔ | Optional - Extra | None | |||
Temperature ^ | ||||||
Temperature ^ | Optional - Extra | Optional - Extra | ||||
Scrolling | ||||||
Scrolling | Programmable | Programmable | ||||
Trip indications: Under Voltage, Over Voltage | ||||||
Trip indications: Under Voltage, Over Voltage | ✔ | ✔ | ||||
Trip indications: Over Load | ||||||
Trip indications: Over Load | ✔ | Optional - Extra | ||||
Startup time delay | ||||||
Startup time delay | ✔ | ✔ | ||||
High/Low cut-off time delay | ||||||
High/Low cut-off time delay | ✔ | ✔ | ||||
Supports Contactor, Relay and Shunt tripping modes | ||||||
Supports Contactor, Relay and Shunt tripping modes | ✔ | ✔ | ||||
Field testing | ||||||
Field testing | ✔ | ✔ | ||||
Fully programmable (on-site/off-site) | ||||||
Fully programmable (on-site/off-site) | ✔ | |||||
Buzzer Drive | ||||||
Buzzer Drive | ✔ | |||||
Manual mode during TRIAC failures | ||||||
Manual mode during TRIAC failures | ✔ | |||||
Available for 110 Volts system countries ^ | ||||||
Available for 110 Volts system countries ^ | Optional - Extra | Optional - Extra | ||||
Programmable Parameters: Under Voltage, Over Voltage, Output voltage, Sensitivity, High/Low Delay, Start-up time delay | ||||||
Programmable Parameters: Under Voltage, Over Voltage, Output voltage, Sensitivity, High/Low Delay, Start-up time delay | ✔ | ✔ | Output voltage, Sensitivity | |||
Additional programmable parameters: CT Ratio, Overload, Overload Delay | ||||||
Additional programmable parameters: CT Ratio, Overload, Overload Delay | ✔ | Optional - Extra | ||||
Password protection | ||||||
Password protection | ✔ |